USE
Water pumps (autoclave systems) Working: the pressure
switch control the working of the electric pump automatically
depending on the preset setting values. At the minimum
setting value , the electric contacts close and consequently
the motor start working. Once the maximum setting
value has been reached, the electric contact open
and the pump switches off.
INSTALLATION
GM/5 has been designed to allow a rapid and simple
installation: one unique setting screw adjusting the
ON and OFF pressure values (fixed differential), also
allowing an easier and quicker setting of the pressure
switch. The cables clamps for the elec tric cables-entry
are placed laterally to make the wiring much easier.
CONSTRUCTION CHARATERISTICS
terminals with M4x8 screws with 8x8mm pressure dice;
Membrane: textile integrated NBR rubber for alimen
tary use push-button: optional on/off push-button,
Connection: galvanized iron flange with female 1/4Ó
connection with revolving nut.
ELECTRIC CONTACTS
NC (normally closed) contacts in brass alloy with
AgNi surfacing .